Casing design checks
CasingDesign.Rate gives each casing string the API ratings - the formulas of API Bulletin 5C3 / API TR 5C3 that produce the
tabulated ratings of API 5CT and 5C2:
- Burst (internal yield): 0.875 x 2 Yp t / D (0.875 = the -12.5 % wall tolerance), to the nearest 10 psi;
- Collapse: by the D/t ratio in four regimes - yield, plastic, transition, elastic - with the API factors A, B, C, F, G as API tabulates them, to the nearest 10 psi;
- Tension (pipe body yield): pi/4 (D^2 - d^2) Yp, to the nearest 1000 lbf.
The wall comes from the string's outside and inside diameters, or from its nominal weight in casingDesign.pipeDimensions (built
in: rows checked against published API 5CT data - add your own). The minimum yield comes from the grade (casingDesign.gradeYield,
API 5CT; L80-13Cr, N80Q ... match their base grade). A string that cannot be rated says why - it is never estimated. A recorded
burst or collapse rating that differs from the API value by more than 2 % is pointed out.
CasingDesign.Check applies simple loads - full evacuation (the fluid gradient outside, nothing inside) at the shoe's TVD, a surface
test pressure, the buoyed string weight - and compares the design factors (rating / load) with casingDesign.designFactors
(defaults: burst 1.25, collapse 1.1, tension 1.4 - an operator's published minimums, Devon Energy at the EPA's 2011 workshop; set
your own). Beside the schematic, CasingDesignTrack shows the ratings and design factors per string in your pressure and force
units (units.forceUnit: klbf, kN, tf ...), failures in the "Failed" status colour.
ISO/TR 10400 also defines newer formulas (ductile-rupture burst from the tensile strength); casingDesign.method is "API 5C3" -
other methods are not yet implemented and are refused rather than replaced.