TheTechIdea OilGas - User guide Developer guide →

Casing design checks

CasingDesign.Rate gives each casing string the API ratings - the formulas of API Bulletin 5C3 / API TR 5C3 that produce the tabulated ratings of API 5CT and 5C2:

The wall comes from the string's outside and inside diameters, or from its nominal weight in casingDesign.pipeDimensions (built in: rows checked against published API 5CT data - add your own). The minimum yield comes from the grade (casingDesign.gradeYield, API 5CT; L80-13Cr, N80Q ... match their base grade). A string that cannot be rated says why - it is never estimated. A recorded burst or collapse rating that differs from the API value by more than 2 % is pointed out.

CasingDesign.Check applies simple loads - full evacuation (the fluid gradient outside, nothing inside) at the shoe's TVD, a surface test pressure, the buoyed string weight - and compares the design factors (rating / load) with casingDesign.designFactors (defaults: burst 1.25, collapse 1.1, tension 1.4 - an operator's published minimums, Devon Energy at the EPA's 2011 workshop; set your own). Beside the schematic, CasingDesignTrack shows the ratings and design factors per string in your pressure and force units (units.forceUnit: klbf, kN, tf ...), failures in the "Failed" status colour.

ISO/TR 10400 also defines newer formulas (ductile-rupture burst from the tensile strength); casingDesign.method is "API 5C3" - other methods are not yet implemented and are refused rather than replaced.