Methods, standards & assumptions
This page states how each number is produced and what it assumes, so results can be reviewed.
Depth references and trajectories
- Positions between survey stations use the minimum curvature method; TVD, dogleg severity (per 100 ft or 30 m), vertical section and closure follow from it.
- TVDSS = TVD minus the datum elevation. Without a survey the well is treated as vertical.
- Survey azimuths are used as given; in cross-sections they are taken as grid north (grid convergence is not applied).
Well barriers
- Envelope colours follow the NORSOK D-010 convention (primary blue, secondary red).
- The two-barrier principle is checked on every leak path from the reservoir to the surroundings. Intact and unverified elements count (unverified ones are flagged); impaired elements count only if your environment says so; failed never.
- Acceptance-criteria references default to NORSOK D-010 Rev 3 tables that were verified; set your own standard and revision.
- Generated barrier sets and leak-path networks are templates (marked planned): review them for each well.
Well barriers by well type
Barrier sets and leak-path networks can be generated for production and injection wells (primary: casing and cement below the packer, packer, completion string, safety valve; secondary: casing and cement above the packer, wellhead, hanger, annulus valve, tree), drilling and workover (primary: the fluid column; secondary: casing cement, casing, wellhead, riser and BOP), and permanent abandonment (below). All generated sets are templates marked planned: review them for each well.
Permanent plug and abandonment
The barrier set is built from the cement plugs in the schematic: the deepest plug is the primary barrier, the next the secondary, a plug near surface the environmental (open hole to surface) barrier; each includes the casing cement behind it over the plug interval and, for primary and secondary, the formation at its base. The checklist verifies:
| Check | Default | Code |
|---|---|---|
| Cement plugs present | - | WP001 |
| A plug above the uppermost source of inflow (perforations, open hole) | - | WP002 |
| Plug length | 100 m, or 50 m on a bridge plug / cement retainer; environmental plug 50 m | WP003 |
| Casing cement behind each plug covers the plug interval (whole cross-section sealed) | - | WP004 |
| A secondary barrier (second plug above the sources) | - | WP005 |
| An environmental plug with its top shallower than the limit | 50 m | WP006 |
| Plugs verified (tag and pressure test) when a barrier set records their status | - | WP007 |
The defaults follow common NORSOK D-010 practice. Verify them against the revision and company standard you work to and set
them in the abandonment section of your environment. The leak-path check counts the plugs and the routes around them (the
casing cement behind a plug and the formation at its base).
MAASP screening
Screening limits come from the outer casing burst rating times a derating, the inner string collapse rating times a derating, the formation at the shoe, and wellhead ratings. This is screening, not a design calculation; use your well-integrity procedures for operating limits.
Cement evaluation
Bond index is the attenuation ratio: BI = log(free-pipe amplitude / measured amplitude) / log(free-pipe amplitude / fully-bonded amplitude), limited to 0-1, with the calibration amplitudes from your environment (replace the defaults with your tool and casing calibration). A cement barrier element is proposed as verified only with enough logged coverage and a continuous length of good bond at least the required isolation length; proposals are reviewed before they change an element.
Formation pressure
Gradients are least-squares fits per zone; zones are found automatically (up to a configured number, each with a minimum number of tests and a minimum gradient contrast). Fluids are typed from the gradient with configurable boundaries (defaults 0.20 and 0.40 psi/ft). Free-fluid levels are the intersections of adjacent gradient lines.
Mud gas
Wetness, balance and character ratios after Haworth, Sellens and Whittaker (1985), AAPG Bulletin 69(8), with configurable bands; ratios are interpreted only where total gas is a show.
Computed curves (shale volume, porosity, saturation)
Parameters come from the petrophysics section of your environment.
- Shale volume from the gamma-ray index IGR = (GR - GR clean) / (GR shale - GR clean): linear (default), Larionov for tertiary rocks 0.083 (2^(3.7 IGR) - 1), Larionov for older rocks 0.33 (2^(2 IGR) - 1), Clavier 1.7 - sqrt(3.38 - (IGR + 0.7)^2), or Steiber IGR / (3 - 2 IGR).
- Density porosity = (matrix density - bulk density) / (matrix density - fluid density); defaults sandstone 2.65 and fresh water 1.0 g/cm3.
- Density-neutron porosity: the average of the two, or the root mean square sqrt((PHID^2 + PHIN^2) / 2), which reduces the gas effect.
- Water saturation (Archie): Sw = (a Rw / (phi^m Rt))^(1/n), defaults a = 1, m = 2, n = 2; bulk volume water = phi x Sw.
Archie assumes clean formations: no shale correction (Simandoux, Indonesia) is applied, so treat Sw in shaly intervals as indicative. Every computed curve states its method and parameters in its description.
Crossplots
- Density-neutron: neutron porosity (limestone units) across, bulk density down (increasing downward, as on standard
charts). Each lithology line runs from its matrix point (the neutron reading in zero-porosity matrix and the matrix density)
to the fluid point, with ticks at 10, 20, 30 and 40 % porosity. The limestone line is exact for a limestone-calibrated
neutron; the sandstone and dolomite offsets depend on the neutron tool and are approximate defaults - set them from your
tool's chart (
crossplots.densityNeutronLines). - Pickett: deep resistivity against porosity on logarithmic axes, with lines of constant water saturation from Archie, porosity = (a Rw / (Rt Sw^n))^(1/m), using the same parameters as the computed saturation curve. Points on the Sw = 100 % line are water-bearing; points to the right of it have lower saturation.
Points can be coloured by zone (from the formation tops; fluid contacts are not zones) or by another curve such as gamma ray.
Borehole images
Planar features are drawn as sinusoids: depth offset = (hole diameter / 2) x tan(dip) x cos(azimuth - dip direction), so the deepest point lies on the down-dip side. Dips are true dips in a vertical-hole geometry; borehole-relative correction for deviated holes is not applied.
Cross-sections
Wells are projected onto the section line at true horizontal distance; beyond the line's ends the end segments are extended. Formation surfaces are straight lines between well picks - a correlation, not a mapped horizon.
What is deliberately not configurable
Physical constants and unit definitions (0.3048 m per ft, the US survey foot, 0.052 psi/ft per ppg) and calculation internals. This protects results from configuration typos.