TheTechIdea OilGas - User guide Developer guide →

Well integrity toolbox

The TheTechIdea.OilGas.Integrity package. Settings: toolboxes.integrity in the environment.

Multi-finger caliper wall loss

MfcAnalysis.Analyze(model, caliperLogSet) interprets a multi-finger caliper (MFC) run - one radius curve per finger, numbered around the tool (fingerCurves, e.g. R01 ... R40), in any length unit. Following KAPPA's Multifinger Caliper Interpretation and Applications (N. Kotlar):

The nominal pipe at each depth is the innermost casing or tubing string covering it (its OD and ID). Results come back as curves (PENE, MLOSS, REDU, OVAL, IDMAX, IDMIN, RWALL, ECC) on the caliper's depths - shown with the usual log tracks - and per joint: maximum penetration and its depth, maximum metal loss, minimum remaining wall, maximum ovality, minimum ID, and the damage class. Joints come from a tally you pass in, or from the casing collar locator (cclMnemonic, cclThreshold - no default, it depends on the tool), with connectionExclusion left out each side of a connection; without either, the statistics are per nominal pipe interval and the result says so. Damage classes are your company's (damageClasses, by maximum penetration) - there is no industry-standard scale, so none is built in. MfcAnalysis.JointsCsv exports the joint table.

Re-rating corroded joints

Rerating.Rerate(model, mfcResult, loads) re-rates each joint with the same API TR 5C3 formulas as the casing design check (burst, collapse in its regime, pipe-body tension), at the joint's measured wall and the nominal OD, and shows each against the nominal rating. Which wall is a decision about the corrosion, not a formula - KAPPA calls it interdisciplinary: isolated pits tend to leak rather than weaken the pipe, uniform loss weakens it. integrity.wallBasis chooses:

API's 0.875 wall-tolerance factor stays in the burst formula as API states it. Loads and design factors are those of the casing design check: collapse with the casing evacuated at the joint's TVD, a surface test pressure, the buoyed weight of string below the joint, against casingDesign.designFactors. A joint penetrated through is rated zero; a grade without a minimum yield is reported, not rated. CorrosionTrack shows the joints beside the schematic (class colour, re-rated burst and collapse as a percentage of nominal, design factors, failures in the Failed colour); Rerating.ToCsv exports them.

Annular casing pressure

Following API RP 90 (Annular Casing Pressure Management) as the US regulator applies it (BSEE NTL 2009-G01, 30 CFR 250 subpart E).

MAWOP - Mawop.For(model, annulus) gives the maximum allowable wellhead operating pressure of an annulus as the lesser of 50 % of the minimum internal yield pressure (MIYP) of the casing being evaluated, 80 % of the MIYP of the next outer casing (for the outermost casing: 30 % of its own MIYP instead) and 75 % of the collapse rating of the inner tubular. MIYP and collapse are the API 5C3 ratings of the casing design check; the next outer casing is one that reaches the wellhead (a liner hung deeper does not bound the annulus). The result names the governing term; a missing rating means no MAWOP, and a recorded MAWOP that differs is pointed out.

Diagnostic test - CasingPressureDiagnostic.Classify(test, mawop) reads a bleed-down / build-up test (the readings, when bleeding started, when the valve was closed): a pressure above 100 psig needs the test; sustained casing pressure must bleed to 0 psig through a 1/2-inch needle valve within 24 hours; pressure that builds up again after the bleed-down is sustained; pressure above the MAWOP is a departure. As RP 90 says, a departure is not by itself an unacceptable risk - it calls for a risk assessment.

Every number is a setting (toolboxes.integrity.casingPressure): the diagnostic threshold, bleed and build-up hours, the zero tolerance and the four MAWOP fractions - for regimes that set them differently.

Well integrity status and the field board

IntegrityStatus.Assess(model, inputs) puts a well in the categories of Norwegian Oil and Gas / Offshore Norge guideline 117:

Category Principle
Red One barrier failure and the other degraded / not verified, or leak to surface
Orange One barrier failure and the other intact, or a single failure may lead to leak to surface
Yellow One barrier degraded, the other intact
Green Healthy well - no or minor integrity issue

Green and yellow comply with the two-barrier principle; orange and red do not and call for diagnosis and a risk assessment. The barrier envelopes come from the well's latest as-built barrier set (an element's Impaired is the guideline's "degraded", Unverified its "not verified"); an element common to both envelopes means a single failure may lead to leak to surface. The other inputs: corroded joints that fail their design factors (7.2) degrade the barrier elements of their string; annulus diagnostics (7.3) - pressure that cannot be kept below the MAWOP is orange, a leak rate above its criteria (not bleeding to zero) is orange, or red when the pressure is above the MAWOP as well; an observed leak to surface is red. Every category comes with its reasons.

FieldIntegrity counts the wells per category and lists them worst first (ToCsv); IntegrityBoardView shows the field as tiles in the category colours (toolboxes.integrity.categoryColors).

Exports follow the environment's units

MfcAnalysis.JointsCsv and Rerating.ToCsv write in the company's units, not the engines' inches and psi: depths in units.depthUnit, walls and diameters in units.diameterUnit, pressures in units.pressureUnit and tension in units.forceUnit, each column named with its unit (top_m, min_remaining_wall_mm, burst_kPa, tension_kN). Numbers are always in the invariant format.